Setup New Users
The TS690 and TS690ID allows up to 15 users to
operate the alarm system, each user is assigned a
user type and 4 digit passcode. User 01 is the
master user which has a default setting of 5678.
User Types
The following user types are available:
Master
User 01-15 can be programmed as the type
“Master”. If the installation company has
programmed the master user for full access, they
will have access to all user menus and options. If
the installation company has programmed the
master user for limited access, they will NOT have
access to “User menu 2" options 6 and 8.
Standard
Users 02-15 can be programmed as the type
“Standard”. This user type can set and unset the
alarm system and access ”User menu 1”.
Holiday
Users 02-15 can be programmed as the type
“Holiday”. This user type can set and unset the
alarm system and access “User menu 1”.
However, the passcode is automatically deleted
from the system when a master user passcode is
used to unset the alarm system. Normally the
master user would assign this passcode type a
temporary user whilst they are away on holiday.
Set Only
Users 02-15 can be programmed as “Set Only”.
This user type allows the alarm system to be set
and access to “User menu 1".
Reset Only
Users 02-15 can be programmed as “Reset Only”.
This user type allows 24hr alarms to be reset and
access to “User menu 1" option 1 to 7 and 9.
Duress
Users 02-15 can be programmed as “Duress”.
When this user type is entered a silent “Panic Alarm”
(i.e., Bell and sounders not triggered) is transmitted
to the central station via the telephone line and
remote signalling device (if fitted). The user will still
be able to set and unset the alarm system and
access “User menu 1".
All other user code types will generate a
“Duress” alarm if the passcode is entered
with the first two digits reversed (e.g., for a
standard passcode of 2580 enter 5280 to
generate a “Duress” alarm). If required, this
feature can be disabled by the installation
company or by making the first two digits of
the passcode the same.
PA Code
Users 02-15 can be programmed as “PA Code”.
When this user type is entered a “Panic Alarm”' is
transmitted to the central station via the telephone
line and remote signalling device (if fitted). The
external sounder(s) and strobe light(s) are also
activated.
Shunt
Users 02-15 can be programmed as “Shunt”.
When this user type is entered the circuits assigned
to the shunt group are isolated. When the
passcode is re-entered the circuits assigned to the
shunt group are reinstated.
This user type will be displayed as “Access”
on the TS790 Starburst remote keypad.
54
Appendices TS690 & TS690ID Installation Manual
Setup users
User No. >--
Alter user type
Standard
Change pass code
New code > -----
Change pass code
New code > 2589
Enterusertype:
=Master
= Standard
= Holiday
User Typ
e
4
1
2
3
ENT
Enter user No.
e.g. 04
Enter master user (5678)
=PACode
= Shunt
7
8
ENT
e.g. 1 for Master
Enter New passcode
ENT
e.g. 2589
=SetOnly
4
= Reset Only
5
=Duress
6
User menu 2
Select Option :-
ENTENT
Setup New Users Flowchart