5. Set the “ENT KEY DISABLE” jumper link to the
required position.
6. Set the “WARD SOUNDER CONTROL” jumper link
to the required position.
7. Finally clip the remote keypad cover onto the
base being careful not to trap any cables or to
obstruct the tamper switch.
Keypad Loudspeaker Connections
A single 16 Ohm loudspeaker may be wired to the
keypad if required. This loudspeaker will follow the
existing keypad sounder and its volume level can
be adjusted by the speaker volume pot (VR1).
The speaker output and volume pot are
only available on the NETLCD keypad.
Engineer’s Keypad
Normally all system programming will be carried
out from one of the installed remote keypads,
however sometimes it may be more convenient
to program the system at the control panel. This
can be achieved by using an “Engineers Keypad”
which is temporarily plugged on to the control
panel (JP2). To convert a standard remote keypad
to an “Engineers Keypad” an Engineer’s interface
lead is required which can be obtained from your
supplier (P/No. NETEKI).
TS700 LEC Installation
The TS700 LEC (Local Expansion Card) is
connected to the “Remote Network” and provides
two additional programmable detection circuits
and a programmable output. The “Remote
Network” may have up to three LECs connected,
as the system will always require at least one
remote keypad.
Always ensure that all power (mains and
battery) is removed before making any
connections to the LEC..
1. Remove the cover from the base and carefully
remove the PCB.
2. If the LEC is being fitted inside the control panel
you may remove the LEC PCB from its base
and secure it to base of the control panel using
self adhesive feet. If required, the tamper
switch may also be disabled by fitting the
jumper link across JP2, see Figure 10.
3. If the LEC is being fitted outside the control
panel, hold the base in position and mark the
two securing holes. Drill and plug the wall, then
pass all cables into the base via the cable
entry points. Secure the base to the wall using
the appropriate fixing screws.
14
System Installation TS690 & TS690ID Installation Manual
1x16Ohm
Loudspeaker
ABCDE
SPK
+
O/P
-
Figure 9. NETLCD Speaker Connections
Control Panel
To TS900
Remote
Keypad
A (Red)
A
AUX
12V
0V
ENGINEERS REMOTE
JP2
C (Yellow)
B
B(Black)
C
D(White)
D
E(Blue)
E
7 Way 0.1" Molex
connector
Figure 10. Engineer’s Keypad Connection
Network
connections
Programmable
output
switched -ve
@100mA
Tamper switch
Fit jumper-link to
disable tamper switch
CABLE ENTRY
CABLE ENTRY
Programmable
detection circuits
I/D selector
CCT B
ED
C
B
LEC I/D
A
12 34
NULL
JP2
TAMPER = JP2 NOT FITTED
NO TAMPER = JP2 FITTED
CCT A
TA
TB
ZA
ZB
O/P
Figure 11. TS700.LEC Layout