Configure Part Sets [2.8]
The TS690 and TS690ID can be configured to have
up to three parts set modes (Part Set A, Part Set B
and Part Set C). This option allows the engineer to
configure each part set mode. Within each part
set mode you must designate which circuits will
remain armed and which circuits will be omitted.
When the user selects the relevant part set mode
the system only arm the circuits that are
designated as armed and isolate the circuits that
are designated as omitted.
Only the circuit types “Night”, “Final Exit” and “Exit
terminator” can be designated as omitted.
View System Log [2.9]
The engineer can use this option to view the
system log. The [A] and [C] keys allow you to scroll
backwards and forwards through the log events.
44
Engineer's Menu 2 TS690 & TS690ID Installation Manual
Configure Omits
for part set A
Front Door
CCT 01 Armed
Circuit text
Select part set mode:.
e.g. Press B
Status
= Next circuit
8
ENT
ENT
A
= Alternate Armed/Omitted
B
= Previous circuit
C
Engineers menu 2
Select Option :-
Front door
CCT 01 Omitted
StarburstLCD
LED
E2 -
ENGR2-
PS A
PSET A
01-A
CCT 01-A
01-O
CCT 01-O
=PartsetA
A
=PartsetB
B
=PartsetC
C
Configure Omits Flowchart
PASSCODE 01
08:40.59 28/04
to alternat
e
Name &
User No.
Date/Time
Event type
= Scroll backwards
9
ESC
A
B
= Scroll forwards
C
Engineers menu 2
Select Option :-
ALARM 02
08:45.59 28/04
to alternate
Circuit No.
&
Circuit Text
Date/Time
Event type
= Scroll backwards
A
B
= Scroll forwards
C
View System Log Flowchart