10 Tamp user reset
When programmed as “Yes", tamper alarms
can be reset by the user. When programmed
as ”No", tamper alarms can only be reset by
the engineer or via remote reset. (Default: Yes)
11 Do battery test
When programmed as "Yes" the control panel
battery and any monitored PSU batteries are
tested every hour and when exiting the
engineer's mode. When programmed as "No"
the control panel battery and any monitored
PSU batteries are not tested. (Default: No)
12 F.Exit is NIGHT
When programmed as “Yes" final exit circuits
change to night circuits when the system is part
set. When programmed as ”No" final exit
circuits remain as final exit circuits when the
system is part set. (Default: No)
13 Use code + Enter
When programmed as “Yes", all passcodes
require an additional press of the [ENT] key to
gain access to the system. When
programmed as ”No", access to the system
only requires the entry of the passcode.
(Default: No)
14 Show P.set disp. (LED Keypads)
When programmed as “Yes" the display will
alternate between showing the time and
wards that are set when the system is part set.
When programmed as ”No" the display will
always show the time when the system is part
set. (Default: Yes)
15 Dial Consec.
When programmed as “Yes", the plug-on
digicom attempts calls consecutively. When
programmed as ”No”, the plug-on digicom
attempts calls alternatively. (Default: Yes)
16 SET with AC off
When programmed as “Yes”, the system can
be set without mains power. When
programmed as “No”, the system cannot be
set without mains power. (Default: Yes)
17 Loud Chime tones
When programmed as “Yes” the chime tones
are always at full volume. When programmed
as “No” the chime tones are at the level set by
VR1 on the main PCB. (Default: No)
18 Invert Output 1
When programmed as “Yes” panel output 1 is
normal. When programmed as “No” panel
output 1 is inverted. (Default: No)
19 Invert Digi O/Ps
When programmed as “Yes” the five digicom
outputs on the control panel switch from 0V to
+12V when active (+ve applied). When
programmed as “No” the five digicom outputs
on the control panel switch from +12V to 0V
when active (+ve removed). (Default: No)
20 On-Line keypad
When programmed as “Yes" the Menvier
Lineload On-Line Keypad feature is enabled.
When programmed as “No” the Menvier
Lineload On-Line Keypad feature is disabled.
(Default: Yes)
21 Restore P.I.D
When programmed as "Yes" the Contact ID
restore status is transmitted. When
programmed as "No" Contact ID restore is not
transmitted. (Default: Yes)
22 User Authorised
When programmed as “Yes” the Menvier
Lineload software can only write information to
the control panel after the user has authorised
remote communications. When
programmed as “No” the Menvier Lineload
software can write information to the control
panel without user authorisation. (Default: No)
23 Mimic Alm & Flt.
When programmed as “Yes” any outputs
programmed as the type "Circuit Alarm" will
activate when the relevant circuit is in alarm or
in a fault condition. When programmed as
“No” any outputs programmed as the type
"Circuit Alarm" will activate when the relevant
circuit is in alarm. (Default: No)
24 Monitor off hook
When programmed as “Yes”, the plug-on
digicom will monitor the telephone line for
off-hook conditions (high security line
monitoring). When programmed as “No”, the
plug-on digicom will only monitor the
telephone line for line cut conditions (low
security). (Default: No)