Cooper TS690 Manual de instalación Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Application
The DC6 digital communicator/modem is suitable
for connection to the following types of telephone
line:
l
Direct exchange lines (PSTN) supporting DTMF
(Tone dialling) or Loop Disconnect (Pulse
Dialling).
l
PABX exchanges (with or without secondary
proceed indication).
The DC6 is only approved for use with
compatible PABXs. Correct operation in all
circumstances is not guaranteed.
The DC6 is fully compatible with BT Network
services.
Only control panels fitted with V2.0 or later
software, or DC6’s fitted with V1.17 or later
software are compatible with Call Minder
and Call Divert services. For full details on
compatibility refer to Technical Bulletin
002/04/98 or contact Technical Support.
Approval
The DC6 digital communicator/modem is not
suitable for connection as an extension to a pay
phone or 1+1 carrier systems. The DC6 digital
communicator/modem is approved for the
following usage:
l
Automatic call initialisation
l
Operation in absence of proceed indication
l
Multiple repeat attempts
l
Modem
Usage other than the approved usage or failure to
comply with the installation and programming
instructions may invalidate any approval given to
the apparatus.
Connections
Connection terminals on the DC6 are described
as "Telecommunications Network Voltage" circuits
(TNV).
It is important that the installer ensures that
TNV connections are only connected to
the PSTN and SELV circuits are only
connected to other circuits designated as
SELV circuits.
Please ensure that cabling to the
telephone line connections (TNV) are
routed well away from the detection
circuitry (SELV) and the cabling to the
detection circuitry (SELV) are routed well
away from the telephone circuitry (TNV).
Interconnection circuits should be such
that the equipment continues to comply
with the requirements of 4.2 of EN 41003 for
TNV circuits and 2.3 of EN 60950 for SELV
circuits, after making connections
between circuits.
19
TS690 & TS690ID Installation Manual System Installation
Telephone cable
Type 1/0.5mm CW130
8
A = 5 - White/Blue ring
B = 2 - Blue/White ring
NOTE
The A1 and B1 telephone connections are not
used on the UK version of the DC6.
6
5
4
ABB1A1
Status
LED
Plug onto
JP4
Telephone Line
Connections
(TNV)
Mounting Pilar
Holes
Mounting Pilar
Holes
3
2
1
Figure 22. DC6 Connections