Extension Loudspeakers
Up to two extension loudspeakers can be
connected across the [SPK+] and [H/O-] terminals
on the control panel PCB. The volume for the
loudspeaker is controlled by VR1 “Speaker
Volume”.
Digicom/RedCARE Installation
A stand alone digital communicator, RedCARE
STU or Paknet interface card can be connected to
the control panel using the following connections:
Digicom Outputs 1 to 5
These are the programmable digicom output
connections. They are normally at +12V and
switch to 0V when active. The outputs can be
inverted so that they switch from 0V to +12V when
active, see System Configuration on page 34.
Each output will source 5mA in the +12V condition
and sink 100mA in the 0V condition.
+DC POWER
This provides the +12V power to the digicom. This
output is un-fused and therefore should only be
used if the digicom is fitted inside the control
panel. The 0V supply for the digicom/STU can be
picked up from any of the auxiliary 0V terminals.
LINE FLT
When this input is switched to +12V, a “Line Fault”
condition is generated. A “Line Fault” condition In
the unset mode will cause a “Chime” type tone to
be generated every minute, which can be
silenced by entering any valid passcode. A “Line
Fault” condition In the set mode will cancel the
“Bell Delay”.
REM RESET
If the system is programmed for “Engineer Reset”,
then after a full alarm the system will require
resetting, normally this is done by the engineer or
coded remote reset. Applying a -ve to this input
terminal will cause the system to reset after a full
alarm. This input could be connected to the
“Control” output on a RedCARE STU so that the
Alarm Receiving Centre can poll the STU and thus
reset the panel.
DC6 Digi-Modem Installation
A plug-on digi-modem DC6 can be fitted inside
the control panel to allow remote interrogation
and programming via a personal computer (PC).
It will also function as a standard digital
communicator. Before attempting to install the
DC6, the installer must be aware of the following:
Regulatory Requirements
The DC6 digi-modem must be installed by an
electrically competent person.
18
System Installation TS690 & TS690ID Installation Manual
1 x 16 Ohm Loudspeaker
2 x 16 Ohm Loudspeakers
SPK+
H/O -
SPK+
H/O -
Figure 20. Loudspeaker Connections
Control
Panel
3GSTU
1
1
+DC POWER
Program
As:-
Active Omit (056)
Alarm (005)
PA (006)
Alarm Conf (011)
LINE FLT
AUX 0V
2
2
3
3
4
4
5
TB1
Channel Inputs are
Programmed as
Positive Removed
TB2
TB3
TB4
Control
Line
Fault
RPS
5
67
0V
NO
NO
NO
NC
NC
NC
8
C
C
C
A+
A+
A+
A+
V+
REM RESET
Note: the default for
Output 1 is Fire (007)
Open (036)
Figure 21. 3GSTU RedCARE Connections