34 Entry Keypad Lock
When programmed as “Yes” then users cannot
unset the system from a keypad during entry.
Program this option as “Yes” if you are installing
a DD243:2002 compliant system and the user
must unset the system with a proximity
detector (“Portable ACE”). The user must
employ a proximity tag to disarm the system
during the entry period.
When programmed as “No” then users can
unset the system from a keypad during entry.
If your make Pset Com. Dly (Eng 1.5.03) =
199 then users can unset the system from
a keypad when the system is part-set.
(Default = No)
35 Tamp as Burg
DD243: 2002 states that alarm signals and
confirmation signals must be transmitted using
certain codes. In some case these codes do
not conform to Cooper Security Ltd’s
implementation of the CID standard. This
option allows you to program the control unit to
send tampers as alarm.
When programmed as “Yes” then the control
unit sends tampers to the ARC as Intruder
Alarm (CID 130). In Fast Format the control unit
transfers the Digicom Tamper output (default
output 8) to the Digicom Alarm output (default
output 3).
When programmed as “No” the control unit
sends all messages as specified in Report
Mode.
(Default = No)
36 Entry Confirmation After 2 circuits
When programmed as “Yes” the control unit
sends a confirmed alarm if an intruder
activates two separate zones after the entry
timer expires. If the control unit is in alarm
before the user starts entry then only one
subsequent zone violation is required.
Note: Select this option if you are installing a
DD243:2002 para 6.4.5 compliant system and
the user must unset the system with a proximity
detector (“Portable ACE”).
Whe programmed as “No” the control unit
sends a confirmed alarm if the intruder
activates one zone after the entry timer
expires. This option does not comply with
DD243:2002.
If you program Confirmation After Entry
as “No” then the setting of this option has
no effect.
37 Unconf Usr Rst
When programmed as “Yes” then users can
reset the system after an unconfirmed alarm.
When programmed as “No” then an engineer
or the ARC must reset the system after an
unconfirmed alarm.
(Default = “Yes”)
38 Keypad PA On
When programmed as “Yes” then the user can
start a PA alarm by pressing keys 1 and 3 at the
same time. Program as “No” to remove this
option.
(Default = “No”.)
38
Engineer’s Menu 1 TS690 & TS690ID Installation Manual
Configuration
Enter Number >--
User reset
Option 07 - Yes
User reset
Option 07 - No
to alternate Yes and No
Option No.
9
B
ENT
Enter configuration No.
e.g.07foruserreset
ENT
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1 -
ENGR 1 -
co.--
CONFIG.--
YES
YES
NO
NO
Configuration Flowchart