To set the system the user first enters their
access code at a keypad or operates a
keyswitch. The control unit starts the exit tone.
Note that the exit time is infinite in this option.
The user then operates the final exit zone and
turns the key in the lock switch to “locked”. The
system sets seven seconds after the lock switch
contacts open.
To unset the system the user turns the lock
switch to “unlocked” (closing the lock switch
contacts). The keypads start a continuous
tone. At this point the user can lock the
lockswitch again without causing any alarm.
When the user opens the final exit zone the
control unit starts the entry timer. The user
completes entry by unsetting the system in the
normal way.
Note that when the user unlocks the lockswitch
the control unit disables Alarm Confirmation.
The control unit enables Alarm Confirmation
again if the user locks the lockswitch without
starting the entry timer.
If an intruder opens the final exit door without
first unlocking the lockswitch then the control
unit immediately starts an unconfirmed alarm.
If the intruder goes on to violate another zone
and you have enabled Alarm Confirmation
then the control unit sends a confirmed alarm.
Do System Print [1.7]
If a printer is connected to the control panel a print
out of all system parameters can be obtained.
34
Engineer’s Menu 1 TS690 & TS690ID Installation Manual
System Print Out
Line Number 001
7
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1 -
ENGR 1 -
001
LINE 001
System Print Flowchart
Setting Mode ?
Enter Group > -
Full Set
by Final Exit
Full Set
by Timed Exit
Enter group:
= Full Set
= Part Set A
= Part Set B
= Part Set C
Set Mode
6
0
A
B
C
e.g. 0 for full set
Select Set Mode:
= Final Exit
= Exit Terminator
= Timed Exit
1
2
3
= Instant
4
ENT
e.g. 3 for timed exit
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1 -
ENGR 1 -
S.BY -
SET.MODE -
F-FE
FULL-F.E
F-TE
FULL-T.E
= Deferred
5
= Lockset
6
Setting Modes Flowchart