Modem Password
This option allows the modem password to be
programmed. The “Modem Password” can be up
to 16 character long and provides a means of
security for remote communications. When using
the “Lineload” software the “Modem Password” in
the site profile must match the “Modem Password”
that is stored in the control panel.
Modem Site No.
This option allows the Modem site number to be
programmed. The “Modem Site No.” is a 4 digit
number that is used as a site reference. When
using the “Lineload” software the “Site Reference”
number in the site profile must match the “Modem
Site No.” that is stored in the control panel.
Program Digicom
This option allows the plug-on digi-modem (DC6)
to be programmed.
Telephone Numbers 1 & 2
The telephone number of the alarm receiver.
Account Numbers 1 & 2
The account (chip) number that allocated to you
by your central station.
Reports To Numbers 1 & 2
The individual channels that will report to the
selected receiver number.
Set/Day Channels
The channels that will report a close (set) and open
(day) conditions.
Restore Channels
The channels that will report a restore (reset)
condition when the input channel has returned to
its original state.
48
Engineer's Menu 2 TS690 & TS690ID Installation Manual
|Call back No.1
Cursor
Enter Tel No.
e.g. 018112345678
ENT
Modem options
Select Option :-
Engineers menu 2
Select Option :-
C
018112345678
Call back N|.1
Tel No.
Tel No.
1
= Call back No 1
2
= Call back No 2
3
= Call back No 3
e.g. 1
LCD Only
Modem Call Back Numbers Flowchart
|Modem Password
Cursor
Enter password.
e.g. 5750
4
ENT
Modem options
Select Option :-
Engineers menu 2
Select Option :-
C
5750
Mod|m Password
Password
Password
LCD Only
Modem Password Flowchart
|Modem Site No.
Cursor
Enter 4 digit site No.
e.g. 0001
5
ENT
Modem options
Select Option :-
Engineers menu 2
Select Option :-
C
0001
Mod|m Site No.
Site No.
Site No.
LCD Only
Modem Site Number Flowchart