Vista de pagina 44
Log Event Codes
45
TS690 & TS690ID Installation Manual Engineer's Menu 2
LCD Starburst LED Description
AC OFF
A.C. OFF
PF
Mains power removed.
AC RESTORED
A.C. ON
Pr
Mains power restored
ACTION ALARM
ALM SENT
AA
Alarm activated when system is part-set.
ALARM 01-38
ALARM 01-38
CA.01-38
Full alarm from circuit (01-38).
AUX/BELL TAMPER
AUX TAMP
AT
Auxiliary tamper activated.
AUXILIARY 01-38
AUX 01-38
Au.01-38
Auxiliary circuit activated.
BATTERY FAULT
BATT FLT
BF
Battery fault (voltage below 10.5V).
BELLS REARM
Time and date of bells reinstatement. Separate from
System re-arm.
BELL TESTED
BELL TST
BT
External bell and strobes tested.
CALL BACK No. 01-03
C. BACK 01-03
CB.01-03
Modem making a call back to remote PC.
CCT OMITTED
OMIT'D 01-38
CO.01-38
Circuits omitted by the user at time of Setting.
CCTS ISOLATED
24HR OM'T
CI
24Hr group omitted during the unset condition.
CCTS TESTED 01-38
TEST'D 01-38
Tc.01-38
The number of circuits tested during Walk Test.
CODE TAMPER
C.TMP 01-04
PT.01-04
Code tamper from keypad 01-04
COMMS ACTIVE
COM ACT
cA
Plug-on digicom active.
COMMS FAILED
COMS FLT
cF
Plug-on digicom failed to communicate.
COMMS SUCCESSFUL
COMS OK
cc
Plug-on digicom communicated successfully.
DATE CHANGED
DATE CHG
Dc
System Date changed.
DEFAULT CODE
DEFLT 01
DF
User passcode (01) reset to 5678 by the engineer.
DELAY ALARM 01-38
DELAY 01-38
AD.01-38
Delayed alarm during a part-set condition.
DURESS 01-31
DUR'SS 01-31
Du.01-31
Duress alarm from user passcode (01-31).
ENTRY 01-38
ENTRY 01-38
En.01-38
Entry timer started by circuit (01-38).
ENTRY ALARM 01-38
EN.ALM 01-38
EA.01-38
Entry timed-out alarm from circuit (01-38).
FACTORY RESTART
FACT. RST
Fr
System “Factory Restarted”.
FIRE ALARM 01-38
FIRE 01-38
FA.01-38
Fire alarm circuit activated.
FIRST KNOCK 01-38
FIRST 01-38
Fn.01-38
The first activation of a Double Knock circuit.
FUSE BLOWN 01
FUSE 01
FB.01
Control Panel 12V Auxiliary Fuse blown.
KEY SWITCH 01-38
KEY.SW 01-38
So.01-38
Keyswitch operation from circuit (01-38).
LINE FAULT
LINE FLT
LF
Telephone line fault detected.
LINE RESTORED
LINE OK
Lr
Telephone line fault restored.
LOCKSET LOCKED
Lock switch placed in “locked” position.
LOCKSET UNLOCKED
Lock switch placed in “unlocked” position.
MODEM LOCK-OUT
LOCK-OUT
LO
Modem failed to communicate.
NO EVENT
NO EVENT
--
No log event.
OMITS REMOVED
OMIT REM
Or
Previously omitted circuits reinstated.