25 Answer Phone Def
When programmed as “Yes”, the plug-on
digi-modem will only answer incoming calls
after a second attempt. When programmed
as “No”, the plug-on digi-modem will answer
incoming calls after the modem ring counter
has expired. (Default: No)
26 Send Open/Close
This configuration option will only effect
Extended format signalling, see configuration
option 08. When programmed as “Yes”, the
plug-on digi-modem will send Open and
Close signals (codes 401 & 409) to the central
station. When programmed as “No”, the
plug-on digi-modem will not send Open and
Close signals (codes 401 & 409) to the central
station. (Default: Yes)
27 Tamper always
This configuration option will only effect
Extended format signalling, see configuration
option 08. When programmed as “Yes”, the
plug-on digi-modem will send tamper alarm
signals (codes 137 & 383) to the central station
at all times. When programmed as “No”, the
plug-on digi-modem will only send tamper
alarm signals to the central station when the
system is set or part set. (Default: No)
28 24Hr Ccts always
This configuration option will only effect
Extended format signalling, see configuration
option 08. When programmed as “Yes”, the
plug-on digi-modem will send 24hr/Auxilliary
alarm signals (codes 135 & 150) to the central
station at all times. When programmed as
“No”, the plug-on digi-modem will only send
24hr/Auxilliary alarm signals to the central
station when the system is set or part set.
(Default: No)
29 Keypad PA Silent
When programmed as “Yes”, pressing 1&3on
the remote keypad will generate a silent PA
alarm. When programmed as “No”, pressing 1
& 3 on the remote keypad will generate an
audible PA alarm. (Default: No)
The Keypad PA feature is only available
on remote keypads fitted with version 4.0
software or above.
30 Sounder on Confirm
When programmed as “Yes” the control unit
activates the internal sounders after a
confirmed alarm and any programmed bell
delay. When programmed as “No” the control
unit starts the internal sounders immediately
after an unconfirmed alarm. (Default = No)
31 Bells on Confirm
When programmed as “Yes” the control unit
activates the external sounders after a
confirmed alarm and any programmed bell
delay. When programmed as “No” the control
unit activates the external bell immediately
after an unconfirmed alarm. (Default = No)
32 Confirmation After Entry
When programmed as “Yes” the control unit
sends a confirmed alarm if the intruder
activates one or two separate zones after the
entry timer expires. To select between one or
two zones use “36 Entry conf 2 cct” When
programmed as “No” the control unit disables
alarm confirmation when a user starts the entry
timer. Use the “No” option to comply with
DD243:2002 paras 6.4.2, 6.4.3, 6.4.4 and
6.4.6.
(Default = No)
33 Confirmation On
When programmed as “Yes” then the Digicom
reports a Channel 3 (005 Intruder) for an
intruder alarm as normal. If a subsequent zone
is triggered within the same set period then the
Digicom reports Channel 7 (011 Confirmed
Alarm). The ARC operator can now inform the
appropriate police authority that the alarm is
confirmed and that this is likely to be a real
break in and not a false alarm.
When programmed as “No” then the control
panel disables Alarm Confirmation and any
Alarm Confirm outputs.
(Default = Yes)