1. Introduction
C Used to enable or disable the Chime facility.
l Used to read the 10-event log. When reading the log, press-
ing << (1) displays earlier events, and >> (3) displays later
events.
System Features
Detectors
The panel provides connections for up to six separate detector zones. Each
zone is a closed circuit loop that can be connected to door contacts or
Passive Infra Red (PIR) detectors. Whe the system leaves the factory all
zones are programmed as Normal Alarm zones. If no device is connected to
a zone, the Installer must program it as Not Used (see "4. Programming").
Zone 5 can be programmed as a Fire zone. When this zone is triggered the
system will give a distinctive two-tone fire alarm. Zone 6 can be programmed
as a Panic Alarm. A Panic Alarm will start a full alarm whether the system is
set or unset.
The panel provides a separate Entry/Exit Zone for a door contact or PIR on
the entrance door. Zone 3 can be programmed as an additional Entry/Exit
zone if required.
All wiring, detectors, bell circuits and the panel lid are protected by an Anti
Tamper loop. If the anti-tamper loop is broken then the panel gives an
audible warning from the internal sounder and lights the Tamper LED if the
panel is unset, or a full alarm if the panel is set.
To power detectors (and other devices) the panel provides a 12 volt positive
and negative Auxiliary Power Output.
Full Setting
To full set the system the user enters a four digit access code. When the
code is complete the panel gives an exit tone and starts the exit timer.
If any zone is open during the exit time then the control panel gives an
interrupted tone. The panel gives an alarm tone from the internal speakers if
the zone remains open at the end of the exit time.
Exit Times
The panel can be programmed with one of five exit delays to allow the user to
leave during setting. The exit delay applies to both full set and part set.
Part Setting
The Installer can program the panel so that certain zones are omitted if the