496574 21
UK
Figure 16 shows the connections for wiring more than one detector to a zone.
Use 8 core alarm cable.
Z5
Z6
E E
A/T
NC C A/T
PIR
9448+
Programmable Output
NC C A/T
PIR
To anti-tamper loop
Note: Program O/P as Latchset
for remaining zones
LATCH
ALARM
TAMP
+12V
0V
LATCH
ALARM
TAMP
+12V
0V
+ -
12V AUX
DATA
CLK
O/P
Figure 16. Connecting Several PIRs per Zone
Note that the programmable output from the control panel should be wired to
the latch input of the detectors.
The power for the detectors is available from the two terminals on the PCB
marked "+ - 12V AUX" (max current 300mA).
Connecting a Communicator
To wire a communicator to the Com connector, use cable Part No. 485127.
(You can obtain this cable from your distributor.) Figure 17 shows the con-
nections available from the cable.
Red (12V)
Blue (PA)
Yellow (Intruder)
Black (0V)
12V
ST2
ST3
0V
12V
PA
Intruder
0V
Com Connector Com Connector Cable, Part No. 485127
Example Connections:
660 Speech Communicator
Figure 17. Com Connector Cable Part No 485127
3. Installation