Initial Start Up
Before applying power to the control panel, ensure that any remote keypad
and all zone circuits are connected. DO NOT connect the 12V terminal to the
external sounder or 12VAUX terminals to the detectors at this stage (see
Figure 16).
1. Apply mains to the control panel.
The green power LED lights and the internal sounder will sound. Ignore
any other lights
2. Key-in the factory default user access code: 1234.
The internal sounder stops. Ignore any other lights.
3. Key-in 0 then R followed by the factory default engineer access code:
7890.
All LEDs, except for a and D, flash.
You are now in programming mode.
4. Open the control panel lid, connect the battery, and complete the
connections between the 12V terminal on the lower connector and the
external sounder.
The external sounder should become silent.
Note: The SAB module in the external sounder will continue to ring until the hold off
supply is connected, or until the bell cover lid tamper switch is closed.
5. Close the panel lid once all the connections are made.
Proceed to program the system as described in "4. Programming".