Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-15
Note – The display might be different according to XCP version and system configuration.
At this time, the XSCF will reset and the XSCF session will disconnect, so please
connect the XSCF again. Only the application of the XSCF firmware is completed.
Note – The work described below applies to a system with redundant XSCF Units.
i) Before updating the firmware, perform the showhardconf(8) command and check the
Status of the XSCF Unit 0/1, which is Active or Standby.
ii) Perform the firmware update in order, beginning with the standby side and then the active
side automatically. After the update on the standby side is completed, the active and standby
sides are switched. At this time, the XSCF reset is done and the XSCF session is
disconnected.
iii) Re-connect the XSCF and log in again.
iv) XSCF firmware update is completed.
v) When the firmware update completes, the active and the standby states of the XSCF unit
have become the opposite of original state. For instance, if the firmware update is executed
on XSCFU#0, when completing the command, XSCFU#1 would become the active side. To
switch the XSCF, execute the switchscf (8) command. To confirm the switching between
XSCFs, execute the showhardconf (8) command and check the Status of the XSCF Unit
0/1, which is Active or Standby.
<Example>
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states. Continue? [y|n] :y
d. To confirm that the XSCF firmware update has finished, use the showlogs(8)
command with the monitor option. Confirm no abnormality is found during the
update. If the "XCP update has been completed" message is displayed in each
XSCF Unit, the firmware update has completed.
4. To complete the update of the OpenBoot PROM firmware, restart the domain.
XSCF> showlogs monitor
:
Jun 20 07:25:48 FF1-1-0 monitor_msg: SCF:XCP update has been
completed (XCP version=1082)