Chapter 4 Operation of the Server 4-5
Power consumption and Exhaust air
To display power consumption and exhaust air of a server, use the power consumption
monitoring function and the airflow incdicator. Power consumption monitoring function and
airflow indicator make it possible to routinely confirm the amount of power consumed on
and airflow emitted while the server is up and running.
Note – The power consumption monitoring function is supported only on M3000 server that
run certain versions of XCP firmware as below. The M4000/M5000/M8000/M9000 servers
do not support the power consumption monitoring function.
- M3000 server; XCP 1081 or later
The airflow indicator is supported only on M3000/M4000/M5000/M8000/M9000 servers that
run certain versions of XCP firmware as below.
- M3000 server; XCP 1082 or later
- M4000/M5000 servers; XCP1100 or later
- M8000/M9000 servers; XCP1090 or later
For specific information about these minimum software and firmware requirements, see the
latest version of the Product Notes (no earlier than the XCP 1081 edition) for your server.
To display the power consumption, use the showenvironment power command. The
results displays the maximum (Permitted AC power consumption) and actual
(Actual AC power consumption) power consumption values. When the power type
is DC [direct-current] power supply, "... DC power ..." is displayed. To display the amount of
exhaust air, use the showenvironment air command. You can also obtain the data of
power consumption and exhaust air using the SNMP agent function.
The following is the showenvironment examples on M3000 server:
Note – Power consumption and airflow values are for reference only. These values vary
depending on factors such as system load.
The showenvironment power and showenvironment air commands do not include
the information of External I/O Expansion Unit and peripheral I/O device. Also, the
M4000/M5000/M8000/M9000 servers do not indicate power consumption by
XSCF> showenvironment air
Air Flow:63CMH
XSCF> showenvironment power
Permitted AC power consumption:470W
Actual AC power consumption:450W