Cooper 9448 Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
496328 Issue 2 3 of 12
9448+/9448ES Technical Specification
Outputs
Bell, Strobe, O/P and AUX are open collector transistor outputs.
Bell 500mA, 12VDC. negative applied.
Strobe 500mA, 12VDC. negative applied.
O/P 100mA, 12VDC. negative applied.
9448+
AUX (for detectors) 300mA, 12VDC.
Communicator Outputs PA and Intruder, 12V positive removed.
9448ES
AUX (for detectors) = 500mA, 12VDC.
Communicator Outputs = PA , Alarm and Fire, 12V logic outputs, -
ve applied in alarm (+ve removed).
LS = can support two parallel connected exter-
nally mounted 16Ohm loudspeakers for
internal sounder or EE tones. Controlled by
Vol. potentiomenter in control panel.
Fuses
9448+
F1 - Battery 1A Slow Blow
F2 - 12V AUX 1A Fast Blow
F3 - 21 VAC 1A Slow Blow
9448ES
F1 - Battery = 2A Anti Surge
F2 - 12V AUX = 1A Fast
F3 - 21 VAC = 2A Anti Surge
Caution: When replacing fuses use the ratings quoted above.
When installed as part of an intruder alarm system this panel is designed to
comply with BS4737 Part 1 for a bell only system.