10 of 12 496328 Issue 2
To Re-enter Programming Mode
You can re-enter programming mode at any time when the panel is not set or
in alarm:
Key-in 0 then ENTER followed by the engineer access code.
All LEDs, except for Power, flash.
You are now in programming mode.
Restoring Factory Defaults
The control panel can retain all programmed information and access codes if
both mains and battery power fail. When power is restored the panel will
simply need resetting with either the user's or engineer's access code.
If the end user forgets the user access code then:
1. Power down the control panel, mains and battery.
2. Locate the pair of Molex pins marked 'RST' near the microcontroller.
3. Place a small screwdriver blade to short between the 'RST' pins.
4. With the blade still across the pins, apply battery power then mains.
The system loads the factory default user and engineer's access codes.
5 Remove the screwdriver blade.
6. Key in 1234.
7 Key in 0 then ENTER followed by 7890.
6 You must now reprogram the access codes.
If you want to return the panel to the factory default settings without changing
the access codes:
1. Enter programming mode (if you are not already there).
2. Key in "98 ENTER" at the keypad.
The system loads the factory default command values but does not
changes the access codes.
To Re-enter Programming Mode 9448+/9448ES