496328 Issue 2 11 of 12
Engineer Walk Test
Allows the engineer to test all devices on the system.
1. Enter programming mode.
2. Key in "97 ENTER".
The panel gives a continuous tone.
3. Open and close each detector contact in turn.
When a detector contact is open the panel gives an interrupted tone and
flashes the zone LED.
4. Press OMIT to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA
zones, zone tampers, and panel and bell tampers. The user's walk test does
not allow this.
User Commands
Set/Unset System User code
Part Set 2 + ENTER + User code
Omit zone Zone number + Omit (repeat for all zones to be
omitted) + User code
Keypad PA 1 + 3
Test Bells 4 + ENTER + User code
Walk Test 5 + ENTER User code
Omit to end test
Change User code 6 + current user code
Current user code again
New user code.
Chime On/Off 7 + ENTER + User code
Read Log 8 + ENTER +User code
<< for earlier events
>> for later events
9448+/9448ES Engineer Walk Test