Display Software History Log : (Micro Board)
CF3000 / DF6000 / FX6000
Date Version Comments
15/08/10 3.3.50 See above
15/09/09 3,03.19 Auto learn locking function
Supports Fan controls ,Technical Input/Technical output
Supports Non Fire Input
Added HMO (House of Multiple Occupancy) requirements as per BS5839 Pt6
Support New EN54 pt2 requirements (Disable address moved to access level 3
and disable LED now is off when delay are implemented)
Download analogue values and Event Log to PC
T1/T2 can be Disable using panel clock or a loop addressable device
AVF programmable 10 to 30s
AVF programmable by zone
Added Bell tone on Class Change
Pre-addressed Auto learn
Added German feature on FAT
Added Polish requirements
Approved to latest EN54 pt 2 :1997 +A1:2006 and EN54 pt 4: 1997
+A1:2002+A2:2006
15/08/08 3.02.03 Calibration of touch screen: This feature has been removed from the power up
menu as well as during reset due to various complaints.
Touch screen calibration is only possible by either panel com or activation of class
Change input during panel power up.
Test device on output modules, support technical timers. Increase the number of
devices alarm LED’s to 24, support Russian, Afrikaans, Vietnamese, Finnish, &
Greek languages. Panel default to “Cooper Logo”, Disable Buzzer at Access level
4. Support T1/T2 features (Swedish as well as Standard ) ,Call point override
facility for T1/T2,T1/T2 override using programmable input on site installer, Support
Swedish Fire Brigade Interface with zone/address location. Printer monitoring
(Paper and head up), Extended walk test (led remains on for 20 seconds), Added
Australian tone on addressable sounders, Added overload Fault on Loop when the
load current is too high. (EN54 pt13 requirement). Added "abnormal comms" fault
condition, when the loop communication is (EN54 Pt13). Support FAT interface
(Fire Brigade interface on the network)Two network protocols V1&V2 (V1 standard
protocol, V2 standard+ FAT interface) update display software using PC.“Display
Program can be erased from panel via HyperTerminal. Press Ctrl-X, then Y. Once
erased, it can be programmed via RS232 with "PanelProg".
Added above features as ECN