Loop Software History Log
CF3000 / DF6000 / FX6000
Date Version Comments
15/08/10 3.2.4.11 See above
15/09/09 3.2.3.19 Auto learn locking function
Supports Fan controls. Technical Input/Technical Output
Supports Non Fire Input
Added HMO (House of Multiple Occupancy) requirements as per BS5839 Pt6
Support New EN54 pt2 requirements. (Disable address moved to access level 3
and Disable LED now is off when delay are implemented)
Download analogue values and Event Log to PC.
T1/T2 can be Disable using panel clock or a loop addressable device.
AVF programmable 10 to 30s
AVF programmable by zone
Added Bell tone on Class Change
Pre-addressed Auto learn
Added German feature on FAT
Added Polish requirements
Approved to latest EN54 pt 2 :1997 +A1:2006 and EN54 pt 4: 1997
+A1:2002+A2:2006
15/08/08 3.2.01
Double Knock 2 devices within a Zone (addressable loop devices as well as panel
outputs), Calibration of Touch Screen: This feature has been removed from the
power up menu as well as during reset due to various complaints. Touch screen
calibration is only possible by either Panel com or activation of Class Change input
during Panel power up. Test Device on Output modules, Support Technical timers.
Increase the number of Devices alarm LED’s to 24, Support Russian, Afrikaans,
Vietnamese, Finnish, & Greek languages. Panel default to “Cooper Logo”, Disable
Buzzer at Access level 4 Support T1/T2 features (Swedish as well as Standard) ,
Call point override facility for T1/T2,T1/T2 override using programmable input on
site installer, Support Swedish Fire Brigade Interface with zone/address location
Printer monitoring (Paper and head up), Extended walk test (led remains on for 20
seconds), Added Australian tone on addressable sounders, Added overload Fault
on Loop when the load current is too high. (EN54 pt13 requirement) Added
"abnormal comms" Fault Condition, when the loop communication is (EN54 Pt13).
Support FAT interface (Fire Brigade interface on the network)Two network
protocols V1&V2 (V1 standard protocol, V2 standard+ FAT interface)Update
Display software using PC.“Display Program can be erased from panel via
HyperTerminal. Press Ctrl-X, then Y.Once erased, it can be programmed via
RS232 with "PanelProg".
Added above features as per ECN
20/07/07 3.0.0 Implemented Autolearn per loop, Integrations of Faults,