BATTERY RESTORE Battery restored to healthy condition
BEAM PAIR #### First activation of a beam pair zone number ####
BELL BOX TAMPER External bell tamper
BELL FUSE Bell fuse tripped
BELL TAMP OMIT Bell tamper omitted after confirmation timer has expired
BELL TESTED:- Bell tested for wards
BELLS ACTIVE:- Bell active for wards
CHANGE CODE ## User code for user ## changed
CHANGE CODE ### User code for user ### changed
CHANGE TAG ## User tag changed for user ##
CHANGE TAG ### User tag changed for user ###
CHNG CODE #### User code changed for user ####
CHNG TAG #### User tag changed for user ####
CNFG CHANGE ### Configuration change for user ###
CNFG CHANGE #### Configuration change for user ####
CODE ## Passcode entered for user number ##
CODE ### Passcode entered for user number ###
CODE #### Passcode entered for user number ####
CODE LOCK # OFF Code lock number # is off
CODE LOCK # ON Code lock number # is on
CODE LOCKED ## User number ## attempted to use their passcode whilst locked-out
CODE LOCKED ### User number ### attempted to use their passcode whilst locked-out
CODE LOCKED #### User number #### attempted to use their passcode whilst locked-out
CODE TAMPER Keypad locked out for 5 minutes due to invalid entry of passcode
COMMS FAILED Plug-on digicom failed to communicate with ARC
COMMS TEST CALL Communications test call started
CONFIG CHANGE ## Configuration change for user ##
DATE CHANGED AT System date changed at
DATE CHANGED TO System date changed to
DEFAULT USER
DEFAULT USER ## User ## set to default settings, including passcode
DEFAULT USER ### User ### set to default settings, including passcode
DEFAULT USER #### User #### set to default settings, including passcode
DEFERRED SET:- Deferred set on wards
DL DISCONNECT FL) Downloader disconnected incorrectly
DL DISCONNECT OK Downloader disconnected
DURESS CODE ## Duress alarm from user number ##
DURESS CODE ### Duress alarm from user number ###
DURESS CODE #### Duress alarm from user number ####
ENG HW DEFAULTED
ENGINEER ARRIVES Engineer is logged on the system
ENGINEER DEPARTS Engineer is logged off the system
ENTRY TIME-OUT:- Entry mode timed out for wards
ENTRY ZONE #### Entry mode started from zone number ####
EXIT CANCELLED:- Exit mode cancelled for wards
EXIT STARTED:- Exit mode started for wards
EXT LINE FAULT External PSTN line in fault condition
EXT LINE RESTORE External PSTN line restored
FACTORY RESTART Factory default loaded
FIRE ALARM #### Fire alarm from zone number ####
FIRE RESET:- Fire Alarm reset
FIRE WARDS:- Fire alarm on wards
FIRST KNOCK #### First activation of zone number #### (zone with Double-Knock attribute)
FROM REMOTE #,## Quick set perform from remote keypad (# = Network, ## =device No)
HI-SECURITY SET: Wards set using “High Security” feature
ID LOOP RESTORED Short circuit cleared from ID loop