Appendix
Page 20 497282
Omitting Zones
Your system may be programmed so that you can omit individual detectors.
This enables you to ignore alarms coming from faulty detectors in non-critical
positions. Refer to the table on page 32 to see which zones can be omitted in
your system.
To omit a zone:
1. Key in an access code (or present a tag).
2. Press 2.
This display shows:
Omit Zone?
3. Press the number of the zone you want to
omit (for example, press 07 to omit zone
7) and then press y.
The sounder gives a double "beep" and
the display shows the zone number
followed by an "o":
Omit Zone 07o
If you try to omit a zone for which this is
not allowed, the display shows an "X"
after the zone number.
Omit Zone 07X
4.
Press X to exit.
Note: To include a zone that was omitted, follow the same procedure.
Pressing y toggles between omit and include.
Normal Alarm Zones
When you next set the system, a message asks you to confirm that you want
to omit the zone. Press y to set the system with the zone omitted. Omission is
not permanent: when you next unset the system, the control unit reinstates
the zone. You must omit the zone each time you prepare to set the system.
24-hour Zones
When you next set the system, there is no message to confirm the omission.
24-hour zones (for example, protecting a fire door) remain omitted until you
reinstate them from the keypad:
1. Key in an access code (or present a tag).
2.
Press 2 followed by the zone number and then y.
3.
Press X to exit.